Cooling towers: operation, maintenance and management
Cooling towers are indispensable in many industrial and commercial cooling and process installations. They work as large heat exchangers: warm process water is distributed at the top of the tower via spray nozzles over a plastic fill pack and comes into contact with air drawn in by a fan. The contact surface in the fill pack ensures efficient heat transfer; in addition, a small part of the water evaporates, allowing the remaining water to be cooled below the ambient temperature. The white plume rising from a cooling tower is not smoke but water vapour. Thanks to this evaporation process, cooling towers can remove heat from processes such as power stations or chemical plants.
Because water is continuously lost through evaporation, the composition of the circulating cooling water changes; solids accumulate and the water must be regularly bled off and topped up. If the water is not properly conditioned, limescale deposits, corrosion or microbiological growth occur. A contaminated cooling tower can lead to loss of performance, wasted energy, breakdowns or even downtime. Moreover, warm spray water provides ideal conditions for Legionella bacteria. Cooling tower owners therefore have legal obligations: the Dutch occupational health and safety information sheet AI‑32 and ISSO 55.3 require a risk analysis and management plan to limit Legionella risks.
AQ Group understands how critical this process is. The company offers an integrated approach to cooling tower management: from water treatment and cleaning to technical maintenance, renovation and Legionella risk analyses. Thanks to chemical and chemical-free water treatment and the use of certified specialists, installations remain safe, efficient and reliable. With good management, your cooling tower stays not only clean, but also sustainable and dependable.
How does a cooling tower work?
The principle behind a cooling tower is simple but effective. Warm process water is pumped to the top of the tower and distributed over a fill pack via spray nozzles. This fill pack increases the contact surface between air and water so that heat transfer and evaporation are optimal. As the water flows down, an axial or centrifugal fan draws air through the fill pack. The fastest water molecules evaporate and take heat with them; the cooled water is collected in the basin at the bottom and returned to the process. The temperature difference between incoming and outgoing cooling water is usually between 5 and 10 °C.
There are different types of cooling towers. In open (wet) cooling towers, the cooling medium comes into direct contact with the ambient air, causing evaporation. Closed cooling towers use a tube bundle: the process medium flows through a galvanised steel coil and is cooled from the outside by recirculating water; this prevents the cooling medium from becoming contaminated. Hybrid or adiabatic cooling towers combine the advantages of wet and dry systems. Whichever variant you use – wet, dry or hybrid – the main components remain the same: fill packs, fan, drift eliminators, spray system and water basin. These components must be kept clean and well maintained for optimal operation.
AQ Group offers suitable service and maintenance for every type of cooling tower. A clean and properly adjusted cooling tower works more efficiently, uses less energy and has a longer service life.
Maintaining your cooling tower
A cooling tower only performs optimally if it is properly maintained. Contamination, limescale and wear reduce cooling efficiency, increase energy consumption and raise the risk of Legionella and unexpected downtime. With periodic maintenance, you keep your installation safe, efficient and reliable, and you automatically comply with the requirements of AI-32, ISSO 55.3 and BRL 6010.
For cooling tower maintenance, AQ Group combines inspection, cleaning and mechanical maintenance in a single service visit. Our certified technicians lubricate bearings, change gearbox oil, check fill packs, spray nozzles and drift eliminators, carry out vibration measurements and balance fans. We work independently of brand and type, on open, closed and hybrid towers, and record every finding in a clear report with concrete recommendations.
Because we offer maintenance, cleaning, water treatment and renovation under one roof, you have just one point of contact who takes complete care of your cooling tower. Would you like to know exactly what a service visit involves? See our page on technical maintenance of cooling towers or request a no-obligation quote.
Cooling towers: operation, maintenance and management

Technical maintenance of cooling towers
Good technical maintenance keeps your cooling tower in top condition and prevents unexpected breakdowns. AQ Group provides brand-independent maintenance in which the core components are systematically checked. This includes carrying out vibration measurements, changing gearbox oil, lubricating bearings and inspecting drift eliminators and spray nozzles. By carrying out this work in good time, the service life of the installation is significantly extended and maintenance costs are kept down.

Cleaning cooling towers
Regular, professional cooling tower cleaning is necessary to prevent Legionella and maintain the efficiency of your cooling tower. AQ Group cleans your cooling tower with experienced specialists and an integrated approach. Periodic cleaning removes limescale, contamination and breeding grounds for Legionella, so that your cooling tower continues to operate safely and efficiently. You can safely leave the cleaning of your cooling tower to the specialists at AQ Group.

Cooling tower renovation
Cooling tower components wear out or become contaminated over time. Fill packs and drift eliminators can deteriorate, geared motors can wear and casing panels can corrode. AQ Group carries out complete cooling tower renovations, including replacing fill packs and drift eliminators, overhauling or replacing geared motors, coating the cooling tower and lowering fans and motors. These renovations extend the technical service life and reduce energy costs.
Why is good cooling tower management important?
A cooling tower requires structural management to continue operating safely, efficiently and sustainably. The main reasons at a glance:
1. Preventing Legionella risks.
Cooling towers contain warm spray water and produce aerosols; these are ideal conditions for the growth and spread of Legionella bacteria. Owners are legally obliged to draw up a risk analysis and management plan in accordance with AI‑32 and ISSO 55.3. Regular cleaning, good water treatment and monitoring prevent contamination and protect employees and local residents.
2. Extending service life.
Corrosion, limescale and wear shorten the service life of cooling towers. Regular maintenance and timely renovations, such as replacing fill packs or lubricating bearings, prevent small defects from turning into costly damage. A well-maintained cooling tower lasts longer and reduces the need for expensive replacements.
3. Lower energy and operating costs.
Contamination reduces heat transfer, so systems have to work harder and use more energy. Keeping cooling towers clean keeps efficiency high and lowers energy costs. Optimising your cooling tower is therefore directly reflected in your operations.
4. Complying with legal obligations.
In addition to AI‑32 and ISSO 55.3, additional standards apply in the Netherlands, such as BRL 6010. These require owners to have cooling towers registered and periodically inspected. AQ Group works in accordance with these standards and can help you with Legionella risk analyses and reports.
One partner for complete peace of mind. By offering water treatment, cleaning, maintenance, renovation and monitoring in one package, AQ Group provides an integrated approach. You have one point of contact and benefit from certified specialists with state‑of‑the‑art equipment.
Frequently asked questions about cooling towers
Why choose AQ Group?
At AQ Group, we combine specialist knowledge with more than 20 years of experience in HVAC systems. We clean climate installations thoroughly and effectively using chemical-technical methods. That means:
Fewer breakdowns and lower energy costs
A healthier indoor climate through improved air quality
Safe, certified working methods
Clear reporting and sustainable solutions