Technical maintenance of cooling towers
Good maintenance is the backbone of every cooling tower. Contamination and wear reduce cooling capacity, which directly affects the reliability, efficiency and safety of your process. Regular, preventive maintenance keeps your cooling tower in top condition, minimises the risk of Legionella, reduces the chance of downtime and extends the service life of installations. AQ Group has certified technicians and many years of experience with all brands and types of cooling towers. Our specialists lubricate bearings, change gearbox oil, check fill packs and spray nozzles and tackle faults proactively. Of course, we work in accordance with the applicable guidelines (AI‑32 and ISSO 55.3) and report all our findings. With professional maintenance from AQ Group, your cooling tower remains safe, efficient and reliable.
What does cooling tower maintenance involve?
Technical maintenance of cooling towers consists of a combination of inspections, cleaning and mechanical work. In practice, it starts with a thorough inspection and cleaning of fill packs and drift eliminators to prevent blockages. Our engineers then check the fans, motors and drives; we lubricate bearings, replace or tension V-belts and check the alignment of gearboxes. Changing gearbox oil and cleaning the water distribution system (spray nozzles and spray pattern) are part of every service visit. We carry out vibration measurements and balance fans to prevent bearing damage and imbalance. Depending on the condition of the installation, we replace or overhaul fill packs, drift eliminators and geared motors. All our work is carried out in accordance with AI‑32 and ISSO 55.3, and we provide a comprehensive report and advice for optimal management. Preventive maintenance gives much more peace of mind than reactive repair: it prevents unexpected downtime and extends the technical service life.
Benefits of regular cooling tower maintenance
Regular maintenance has tangible benefits. It maintains reliability and cooling capacity and minimises Legionella risks. Keeping fill packs and drift eliminators clean allows heat exchangers to work optimally, which lowers energy consumption and makes the installation more cost-effective. Well-lubricated bearings and balanced fans limit wear and prevent expensive repairs. A maintenance programme also prevents biofilm and contamination from encouraging the growth of Legionella. In addition, periodic inspections mean you automatically comply with the legal obligations of AI‑32 and ISSO 55.3. Poor maintenance, on the other hand, leads to loss of efficiency, higher energy costs and health risks. AQ Group combines technical maintenance with water treatment and cleaning for an integrated approach. We offer both chemical and chemical-free solutions; for example, our Sonoxide®/Neuthox® technology provides environmentally friendly disinfection without chemicals. With one partner for maintenance, water treatment and cleaning, you can be sure of efficiency, insight and certainty.
Brand-independent maintenance and inspection
Every cooling tower is different. That is why AQ Group works independently of brand and type – whether open or closed towers. Our technicians are trained to carry out maintenance on all common brands and can replace parts with alternatives of equivalent quality. During every service visit, we carry out a complete inspection and draw up a report with findings and recommendations for optimisation. The report also includes any repairs or renovation work required, such as replacing fill packs and drift eliminators, overhauling geared motors or coating the cooling tower. Thanks to this brand-independent approach, you always receive objective advice about your installation and are not tied to a particular brand. If it becomes clear during maintenance that renovation would be worthwhile, AQ Group can coordinate this straight away – extending the service life and saving on energy costs.
Safety, certification and sustainability
Safety and hygiene have the highest priority in cooling tower maintenance. AQ Group works in accordance with the AI‑32 and ISSO 55.3 guidelines and holds ISO‑9001, ISO‑14001, ISO‑45001, VCA** and BRL‑6010 certifications. This means you can rely on our procedures complying with occupational health and safety and environmental legislation. We keep a logbook for every cooling tower with maintenance work, changes and inspection results, as required by the Dutch Environmental Activities Decree (Bal). Sustainability plays an increasingly important role; that is why we use energy-efficient methods and sustainable materials and recommend chemical-free water treatment. The Sonoxide® Plus combines ultrasonic sound waves and UV‑C to kill bacteria without harmful chemicals, while Neuthox® disinfects the cooling water and saves costs at the same time. We also work with environmentally friendly cleaning agents and apply maintenance strategies that extend the service life of components. In this way, responsible maintenance contributes to a safe working environment and a better environment.
Cooling tower maintenance as part of complete management
A cooling tower only functions optimally when all parts of the system are aligned. At AQ Group, we therefore see maintenance as part of integrated cooling tower management: water treatment, cleaning, technical maintenance, renovation and Legionella management. Correct water treatment prevents corrosion, deposits and microbiological growth, while periodic cleaning reduces the risk of Legionella and maintains efficiency. Technical maintenance extends the service life of components and renovation prevents expensive replacements. Because AQ Group has all disciplines in-house, you have one point of contact for the entire process. This saves time, avoids discussions between suppliers and provides a clear overview of costs and planning. Together, we draw up a maintenance plan that suits your process and the regulations, so that you can keep producing without worries.

